The machining method is the workpiece fixed and the tools rotate and feed.The bed of machine is double rectangle guideway. The guide carriage is move on the linear guideway by the hydraulic and the workpiece is fixed by taper hole position.It adopts Taiwan Yongzhen hydraulic station.The colling system is ground oil tank structure.The filtrate method is chip conveyor–magnetism separator–fine filtration three grade and the filtrate precision can reach 50 μ. The CNC system is Germany SIEMENS system. The length of cylinder below 3m is feeded by the lead screw and over 3m is by gear–racked. The efficiency of processing is 3–5 times of traditional deep hole machine if use the Germany Wenaroll high efficiency auto combination tools.
| Main Specifications and Features | TZK25(1 – 8m) | TZK36(1 – 8m) |
| The range of boring diameter | φ80 – φ250mm | φ100 – φ360mm |
| The range of boring depth | 500 – 8000mm | 500 – 8000mm |
| The width of the machine guide way | 600mm | 600mm |
| The height from the guide way to center of spindle | 400mm | 500mm |
| Range of feeding speed | 10 – 3500mm/min (stepless) | 10 – 3500mm/min (stepless) |
| The main motor of boring box | N = 60kW, SIEMENS AC spindle motor | N = 113kW, SIEMENS AC spindle motor |
| Range and kinds of drill box spindle speed | 60 – 1200r/min, two grade stepless | 150 – 800r/min, three grade stepless |
| The workpiece clamped diameter | φ100 – φ350mm | φ120 – φ420mm |
| Feeding motor | N = 7.75kW, AC servo motor | N = 7.75kW, AC servo motor |
| CNC system | SIEMENS 828 | SIEMENS 840 |
| Hydraulic pump motor | N = 2.2kW, n = 1440r/min | N = 2.2kW, n = 1440r/min |
| Cooling pump motor | N = 7.5kW n = 1440r/min, two groups, one group is controlled by frequency conversion | N = 11kW n = 1440r/min, two groups, one group is controlled by frequency conversion |
| The rated pressure of cooling system | 0.6Mpa | 0.6Mpa |
| The motor of extract pump | N = 11kW n = 1440r/min, two groups | N = 11kW n = 1440r/min, two groups |
| The flow of cooling system | 100 – 800L/min, two groups, one group is controlled by frequency conversion | 100 – 1200L/min, two groups, one group is controlled by frequency conversion |